Schneider Electric (RCBO) Acti9 ICV40N - 3P+N - C40 - 6000A - A -SI Type - 30mA

    Description

    This modular acti9 ICV40N error voltage circuit breaker is a plant control switch equipped with earth closure protection. It is a 3P+N error voltage control switch with 3 protected poles and a connected neutral conductor, a nominal current of 40 A and passage current characteristics C. The earth closure protection class is type A-SI with the earth's sensitivity of 30 mA. The earth closure protection is triggered immediately and has no time delay. The ICN unloading capacity is 6000 A at 400 VAC according to EN/IEC 61009-2-1.

    This error voltage circuit breaker protects circuit circuits from short circuits, overload currents, dangerous electrical blows and fire. The two one-time visitrip indicators shorten the search for the triggered line protection switch by clearly displaying it. The green visitors guarantee the physical opening of the contacts to enable downstream maintenance. This product corresponds to standard EN/IEC 61009-2-1 for fault voltage control switch. This Schneider Electric error voltage control switch has an electric lifespan of up to 10,000 cycles and a mechanical lifespan of up to 20,000 cycles.

    The assigned UE operating voltage is 230 VAC. The assigned UI insulation voltage is 440 VAC. The assigned UIMP-incorrect resistance is 4 kv. The network frequency is 50/60 Hz. For modular installation on DIN rail. The width of this fault voltage circuit breaker is 5 modules of 18 mm each. This product is designed in the color white (RAL 9003). The dimensions are 90 mm (W) x 93 mm (h) x 73 mm (t). The weight is 500 g. According to the IEC 60529 standard, the protection class IP20 is. It increases to IP40 in assembly in a modular housing with insulating class II. The operating temperature is between -25 ° C and 60 ° C. The storage temperature is between -40 ° C and 85 ° C.

    Schneider Electric (RCBO) Acti9 ICV40N - 3P+N - C40 - 6000A - A -SI Type - 30mA

      Product shape
      Free collection in Our business (e)

      €220,15 VAT included

      In stock - in 2 to 3 working days with you
        If you inside 10 Stdn. 50 Min. ordered
        Line Icon Line Icon Line Icon
        Ordered icon
        Ordered
        Today
        Sent icon
        Sent
        Delivered icon
        Delivered
        Delivery icon
        Free Shipping

        From 39 €*

        German company

        Shipping from Würzburg

        Customer care icon
        Personal service 24/7

        We are at your side if you have any questions

        Return icon
        30 days of right of return

        Risk -free thanks to satisfaction guarantee

        Sku: EL-SE-ACT9-ICV40N-3P-C40-30MA-A-011
        EAN: 3606480701085

        FAQ

        Here you get to our Faqs

        • Schneider Electric GmbH,
          Gothaer Strasse 29,
          40880, Ratingen,
          Germany, https://www.se.com/de/de/,
          DE-Schneider-Service@SE.com, 093916035000

        Description

        This modular acti9 ICV40N error voltage circuit breaker is a plant control switch equipped with earth closure protection. It is a 3P+N error voltage control switch with 3 protected poles and a connected neutral conductor, a nominal current of 40 A and passage current characteristics C. The earth closure protection class is type A-SI with the earth's sensitivity of 30 mA. The earth closure protection is triggered immediately and has no time delay. The ICN unloading capacity is 6000 A at 400 VAC according to EN/IEC 61009-2-1.

        This error voltage circuit breaker protects circuit circuits from short circuits, overload currents, dangerous electrical blows and fire. The two one-time visitrip indicators shorten the search for the triggered line protection switch by clearly displaying it. The green visitors guarantee the physical opening of the contacts to enable downstream maintenance. This product corresponds to standard EN/IEC 61009-2-1 for fault voltage control switch. This Schneider Electric error voltage control switch has an electric lifespan of up to 10,000 cycles and a mechanical lifespan of up to 20,000 cycles.

        The assigned UE operating voltage is 230 VAC. The assigned UI insulation voltage is 440 VAC. The assigned UIMP-incorrect resistance is 4 kv. The network frequency is 50/60 Hz. For modular installation on DIN rail. The width of this fault voltage circuit breaker is 5 modules of 18 mm each. This product is designed in the color white (RAL 9003). The dimensions are 90 mm (W) x 93 mm (h) x 73 mm (t). The weight is 500 g. According to the IEC 60529 standard, the protection class IP20 is. It increases to IP40 in assembly in a modular housing with insulating class II. The operating temperature is between -25 ° C and 60 ° C. The storage temperature is between -40 ° C and 85 ° C.

        Recently viewed

        • Mehrwertsteuerbefreiung für Solaranlagen 2024: Ein Überblick für Deutschland, Österreich und die Schweiz - NeueEnergie24

          VAT exemption for solar systems 2024: An overview for Germany, Austria and Switzerland

          Read more 

        • Die Verschiebung des "Solarpaket 1" – Ein Rückschritt für die Energiewende? - NeueEnergie24

          The shift of "solar package 1" - a step backwards for the energy transition?

          Read more 

        • Deutschlands revolutionäres Solarpaket I: Auf dem Weg zu einer strahlenden Zukunft - NeueEnergie24

          Germany's revolutionary solar package I: On the way to a radiant future