ABB ABB S203-B40NA Miniature Circuit Breaker - 3+NP - B - 40 A
The circuit breakers of the S 200 series protect cables and lines against overload and short circuits in accordance with DIN VDE 0100-430 and DIN VDE 0100-530. They comply with the construction regulations DIN VDE 0641-11 or IEC/EN 60898-1, DIN VDE 0660-101 or IEC/EN60947-2 and UL1077. Their patented connection terminal ensures simple and safe contact and handling using a pressure plate. For better visibility when wiring, the connection opening for cables is located above the connection opening for the phase busbar. Conductor cross-sections of up to 35 mm² can be connected directly to the device via the connection terminal with insulation in protection class IP20. The extensive range of accessories offers you everything you need for your installation tasks. Numerous approvals make the S 200 fit for worldwide use. Each device is subjected to three intensive tests for quality and performance before delivery.
€111,86
ABB ABB S201-B40NA Miniature Circuit Breaker - 1+NP - B - 40 A
The circuit breakers of the S 200 series protect cables and lines against overload and short circuits in accordance with DIN VDE 0100-430 and DIN VDE 0100-530. They comply with the construction regulations DIN VDE 0641-11 or IEC/EN 60898-1, DIN VDE 0660-101 or IEC/EN60947-2 and UL1077. Their patented connection terminal ensures simple and safe contact and handling using a pressure plate. For better visibility when wiring, the connection opening for cables is located above the connection opening for the phase busbar. Conductor cross-sections of up to 35 mm² can be connected directly to the device via the connection terminal with insulation in protection class IP20. The extensive range of accessories offers you everything you need for your installation tasks. Numerous approvals make the S 200 fit for worldwide use. Each device is subjected to three intensive tests for quality and performance before delivery.
€47,60
ABB ABB S201-B32NA Miniature Circuit Breaker - 1+NP - B - 32 A
The circuit breakers of the S 200 series protect cables and lines against overload and short circuits in accordance with DIN VDE 0100-430 and DIN VDE 0100-530. They comply with the construction regulations DIN VDE 0641-11 or IEC/EN 60898-1, DIN VDE 0660-101 or IEC/EN60947-2 and UL1077. Their patented connection terminal ensures simple and safe contact and handling using a pressure plate. For better visibility when wiring, the connection opening for cables is located above the connection opening for the phase busbar. Conductor cross-sections of up to 35 mm² can be connected directly to the device via the connection terminal with insulation in protection class IP20. The extensive range of accessories offers you everything you need for your installation tasks. Numerous approvals make the S 200 fit for worldwide use. Each device is subjected to three intensive tests for quality and performance before delivery.
€46,41
ABB ABB S201-B25NA Miniature Circuit Breaker - 1+NP - B - 25 A
The circuit breakers of the S 200 series protect cables and lines against overload and short circuits in accordance with DIN VDE 0100-430 and DIN VDE 0100-530. They comply with the construction regulations DIN VDE 0641-11 or IEC/EN 60898-1, DIN VDE 0660-101 or IEC/EN60947-2 and UL1077. Their patented connection terminal ensures simple and safe contact and handling using a pressure plate. For better visibility when wiring, the connection opening for cables is located above the connection opening for the phase busbar. Conductor cross-sections of up to 35 mm² can be connected directly to the device via the connection terminal with insulation in protection class IP20. The extensive range of accessories offers you everything you need for your installation tasks. Numerous approvals make the S 200 fit for worldwide use. Each device is subjected to three intensive tests for quality and performance before delivery.
€45,22
ABB ABB S201-B20NA Miniature Circuit Breaker - 1+NP - B - 20 A
The circuit breakers of the S 200 series protect cables and lines against overload and short circuits in accordance with DIN VDE 0100-430 and DIN VDE 0100-530. They comply with the construction regulations DIN VDE 0641-11 or IEC/EN 60898-1, DIN VDE 0660-101 or IEC/EN60947-2 and UL1077. Their patented connection terminal ensures simple and safe contact and handling using a pressure plate. For better visibility when wiring, the connection opening for cables is located above the connection opening for the phase busbar. Conductor cross-sections of up to 35 mm² can be connected directly to the device via the connection terminal with insulation in protection class IP20. The extensive range of accessories offers you everything you need for your installation tasks. Numerous approvals make the S 200 fit for worldwide use. Each device is subjected to three intensive tests for quality and performance before delivery.
€45,22
ABB ABB FH204 A-40/0.03 residual current circuit breaker 4P type A 30 mA
The FH200 series RCCBs ensure protection for persons and installations against fault currents to earth. A comprehensive range of standard instantaneous tripping devices (AC) and Type A products are particularly suitable for installation in residential applications.
€69,02
ABB ABB DS203NC C32 A300 residual current circuit breaker with overcurrent protection
Residual current circuit breakers (RCBOs) offer personal and material protection as well as protection against electrically ignited fires in accordance with DIN VDE 0100-410 and DIN VDE 0100-530. They guarantee protection of three single-phase or three-phase circuits against overload and short-circuit currents, protection against sinusoidal alternating currents and pulsating currents with a smooth DC residual current component of up to 6 mA against earth. As well as fault protection (protection against indirect contact), additional protection (with IΔn ≤ 30 mA) and fire protection (with I∆n ≤ 300 mA). They meet the product standard IEC/EN 61009-1 (VDE 0664-20). Areas of application are household, commercial and industrial applications. The extensive range of accessories offers you everything you need for your installation tasks. Numerous approvals make the DS203NC fit for worldwide use. Rated switching capacity Icn = 6,000 A according to IEC/EN 61009-1 (VDE 0664-20) for RCDs (residual current devices) in residential buildings and similar applications, Icu = 10 kA according to IEC/EN 60947-2 (VDE 0660-101) for MCBs (LS) in industrial applications. RCBO DS203NC A Type A is 3-pole protected (LS), 4-pole switching and can be used in three-phase networks with or without N-conductor.
€224,91
ABB ABB DS203NC C32 A30 residual current circuit breaker with overcurrent protection
Residual current circuit breakers (RCBOs) offer personal and material protection as well as protection against electrically ignited fires in accordance with DIN VDE 0100-410 and DIN VDE 0100-530. They guarantee protection of three single-phase or three-phase circuits against overload and short-circuit currents, protection against sinusoidal alternating currents and pulsating currents with a smooth DC residual current component of up to 6 mA against earth. As well as fault protection (protection against indirect contact), additional protection (with IΔn ≤ 30 mA) and fire protection (with I∆n ≤ 300 mA). They meet the product standard IEC/EN 61009-1 (VDE 0664-20). Areas of application are household, commercial and industrial applications. The extensive range of accessories offers you everything you need for your installation tasks. Numerous approvals make the DS203NC fit for worldwide use. Rated switching capacity Icn = 6,000 A according to IEC/EN 61009-1 (VDE 0664-20) for RCDs (residual current devices) in residential buildings and similar applications, Icu = 10 kA according to IEC/EN 60947-2 (VDE 0660-101) for MCBs (LS) in industrial applications. RCBO DS203NC A Type A is 3-pole protected (LS), 4-pole switching and can be used in three-phase networks with or without N-conductor.
€211,82
ABB ABB DS203NC C25 A300 residual current circuit breaker with overcurrent protection
Residual current circuit breakers (RCBOs) offer personal and material protection as well as protection against electrically ignited fires in accordance with DIN VDE 0100-410 and DIN VDE 0100-530. They guarantee protection of three single-phase or three-phase circuits against overload and short-circuit currents, protection against sinusoidal alternating currents and pulsating currents with a smooth DC residual current component of up to 6 mA against earth. As well as fault protection (protection against indirect contact), additional protection (with IΔn ≤ 30 mA) and fire protection (with I∆n ≤ 300 mA). They meet the product standard IEC/EN 61009-1 (VDE 0664-20). Areas of application are household, commercial and industrial applications. The extensive range of accessories offers you everything you need for your installation tasks. Numerous approvals make the DS203NC fit for worldwide use. Rated switching capacity Icn = 6,000 A according to IEC/EN 61009-1 (VDE 0664-20) for RCDs (residual current devices) in residential buildings and similar applications, Icu = 10 kA according to IEC/EN 60947-2 (VDE 0660-101) for MCBs (LS) in industrial applications. RCBO DS203NC A Type A is 3-pole protected (LS), 4-pole switching and can be used in three-phase networks with or without N-conductor.
€221,34
ABB ABB DS203NC C25 A30 residual current circuit breaker with overcurrent protection
Residual current circuit breakers (RCBOs) offer personal and material protection as well as protection against electrically ignited fires in accordance with DIN VDE 0100-410 and DIN VDE 0100-530. They guarantee protection of three single-phase or three-phase circuits against overload and short-circuit currents, protection against sinusoidal alternating currents and pulsating currents with a smooth DC residual current component of up to 6 mA against earth. As well as fault protection (protection against indirect contact), additional protection (with IΔn ≤ 30 mA) and fire protection (with I∆n ≤ 300 mA). They meet the product standard IEC/EN 61009-1 (VDE 0664-20). Areas of application are household, commercial and industrial applications. The extensive range of accessories offers you everything you need for your installation tasks. Numerous approvals make the DS203NC fit for worldwide use. Rated switching capacity Icn = 6,000 A according to IEC/EN 61009-1 (VDE 0664-20) for RCDs (residual current devices) in residential buildings and similar applications, Icu = 10 kA according to IEC/EN 60947-2 (VDE 0660-101) for MCBs (LS) in industrial applications. RCBO DS203NC A Type A is 3-pole protected (LS), 4-pole switching and can be used in three-phase networks with or without N-conductor.
€161,84
ABB ABB DS203NC C20 A300 residual current circuit breaker with overcurrent protection
Residual current circuit breakers (RCBOs) offer personal and material protection as well as protection against electrically ignited fires in accordance with DIN VDE 0100-410 and DIN VDE 0100-530. They guarantee protection of three single-phase or three-phase circuits against overload and short-circuit currents, protection against sinusoidal alternating currents and pulsating currents with a smooth DC residual current component of up to 6 mA against earth. As well as fault protection (protection against indirect contact), additional protection (with IΔn ≤ 30 mA) and fire protection (with I∆n ≤ 300 mA). They meet the product standard IEC/EN 61009-1 (VDE 0664-20). Areas of application are household, commercial and industrial applications. The extensive range of accessories offers you everything you need for your installation tasks. Numerous approvals make the DS203NC fit for worldwide use. Rated switching capacity Icn = 6,000 A according to IEC/EN 61009-1 (VDE 0664-20) for RCDs (residual current devices) in residential buildings and similar applications, Icu = 10 kA according to IEC/EN 60947-2 (VDE 0660-101) for MCBs (LS) in industrial applications. RCBO DS203NC A Type A is 3-pole protected (LS), 4-pole switching and can be used in three-phase networks with or without N-conductor.
€224,91
ABB ABB DS203NC C16 A300 residual current circuit breaker with overcurrent protection
Residual current circuit breakers (RCBOs) offer personal and material protection as well as protection against electrically ignited fires in accordance with DIN VDE 0100-410 and DIN VDE 0100-530. They guarantee protection of three single-phase or three-phase circuits against overload and short-circuit currents, protection against sinusoidal alternating currents and pulsating currents with a smooth DC residual current component of up to 6 mA against earth. As well as fault protection (protection against indirect contact), additional protection (with IΔn ≤ 30 mA) and fire protection (with I∆n ≤ 300 mA). They meet the product standard IEC/EN 61009-1 (VDE 0664-20). Areas of application are household, commercial and industrial applications. The extensive range of accessories offers you everything you need for your installation tasks. Numerous approvals make the DS203NC fit for worldwide use. Rated switching capacity Icn = 6,000 A according to IEC/EN 61009-1 (VDE 0664-20) for RCDs (residual current devices) in residential buildings and similar applications, Icu = 10 kA according to IEC/EN 60947-2 (VDE 0660-101) for MCBs (LS) in industrial applications. RCBO DS203NC A Type A is 3-pole protected (LS), 4-pole switching and can be used in three-phase networks with or without N-conductor.
€234,43
ABB ABB DS203NC C16 A30 residual current circuit breaker with overcurrent protection
Residual current circuit breakers (RCBOs) offer personal and material protection as well as protection against electrically ignited fires in accordance with DIN VDE 0100-410 and DIN VDE 0100-530. They guarantee protection of three single-phase or three-phase circuits against overload and short-circuit currents, protection against sinusoidal alternating currents and pulsating currents with a smooth DC residual current component of up to 6 mA against earth. As well as fault protection (protection against indirect contact), additional protection (with IΔn ≤ 30 mA) and fire protection (with I∆n ≤ 300 mA). They meet the product standard IEC/EN 61009-1 (VDE 0664-20). Areas of application are household, commercial and industrial applications. The extensive range of accessories offers you everything you need for your installation tasks. Numerous approvals make the DS203NC fit for worldwide use. Rated switching capacity Icn = 6,000 A according to IEC/EN 61009-1 (VDE 0664-20) for RCDs (residual current devices) in residential buildings and similar applications, Icu = 10 kA according to IEC/EN 60947-2 (VDE 0660-101) for MCBs (LS) in industrial applications. RCBO DS203NC A Type A is 3-pole protected (LS), 4-pole switching and can be used in three-phase networks with or without N-conductor.
€183,26
ABB ABB DS201 C25 A30 residual current circuit breaker with overcurrent protection
The DS201 series is a 1P+N RCBO in two-module width for the protection of single-phase consumer circuits against overload and short-circuit currents; protection against the effects of sinusoidal alternating and direct pulsating earth fault currents; protection against indirect contacts and additional protection against direct contacts (with sensitivity = 30 mA).
€166,60
ABB ABB DS201 C20 A30 residual current circuit breaker with overcurrent protection
Residual current circuit breakers (RCBOs) offer personal and material protection as well as protection against electrically ignited fires in accordance with DIN VDE 0100-410 and DIN VDE 0100-530. They ensure protection of single-phase circuits against overload and short-circuit currents, protection against sinusoidal alternating currents and pulsating currents with a smooth DC residual current component of up to 6 mA to earth. As well as fault protection (protection against indirect contact), additional protection (with IΔn ≤ 30 mA) and fire protection (with IΔn ≤ 300 mA). They meet the product standards IEC/EN 61009-1 (VDE 0664-20), IEC/EN 61009-2-1 (VDE 0664-21). Areas of application include household, commercial and industrial applications. The extensive range of accessories offers you everything you need for your installation tasks. Numerous approvals make the DS201 suitable for worldwide use. Rated switching capacity according to IEC/EN 61009 Icn = 6 kA. RCBO DS201 A Type A is 1-pole protected (LS), 2-pole switching.
€155,89
ABB ABB DS201 B25 A30 residual current circuit breaker with overcurrent protection
Residual current circuit breakers (RCBOs) offer personal and material protection as well as protection against electrically ignited fires in accordance with DIN VDE 0100-410 and DIN VDE 0100-530. They ensure protection of single-phase circuits against overload and short-circuit currents, protection against sinusoidal alternating currents and pulsating currents with a smooth DC residual current component of up to 6 mA to earth. As well as fault protection (protection against indirect contact), additional protection (with IΔn ≤ 30 mA) and fire protection (with IΔn ≤ 300 mA). They meet the product standards IEC/EN 61009-1 (VDE 0664-20), IEC/EN 61009-2-1 (VDE 0664-21). Areas of application include household, commercial and industrial applications. The extensive range of accessories offers you everything you need for your installation tasks. Numerous approvals make the DS201 suitable for worldwide use. Rated switching capacity according to IEC/EN 61009 Icn = 6 kA. RCBO DS201 A Type A is 1-pole protected (LS), 2-pole switching.
€140,42
ABB ABB C11 110-101 MID
AC meter for measuring single-phase networks via a direct connection for currents up to a maximum of 40 A. The meter is calibrated according to MID and approved according to IEC. Display of all important instrumental values. The electricity meter has one output. This can be used either as a pulse output to output the active energy or as an alarm output. Up to 25 alarm values (threshold values with time delay) can be set here. The installation width is 1 DIN module. Suitable accessories such as current transformers, gateways with integrated web server and a KNX interface can be found in our portfolio.
€97,58
ABB ABB B23 311-100 three-phase meter
Three-phase meter for measuring a three-wire or four-wire three-phase network via a direct connection up to a maximum of 65 A. The following values are output via a seven-segment display with up to 7 digits: active energy (class 1) and reactive energy (class 2) for import and export, power, currents, voltages (LL, LN), frequency, cos phi, power factor and apparent power, both per phase and total. Communication can take place via the integrated infrared interface for connecting a KNX module. The energy meter has 2 permanently configured inputs and outputs. The output can be used either as a pulse output to output active or reactive energy or as an alarm output. Up to 25 alarm values (threshold values with time delay) can be set here. The inputs are used to control the tariffs or to count external pulses. The resettable intermediate counter enables the measurement of individual intervals. The meter also records up to 4 tariffs. The meter is calibrated according to MID and approved according to IEC. The installation width is 4 DIN modules.
€446,25
ABB ABB B23 212-100 YCU.00152 Three-phase meter
Three-phase meter for measuring a three-wire or four-wire three-phase network via a direct connection up to a maximum of 65 A. The following values are output on a white backlit display with up to 7 digits: active energy (class 1) and reactive energy (class 2) for import and export, power, currents, voltages (LL, LN), frequency, cos phi, power factor and apparent power, both per phase and total. Communication can take place via the integrated RS485 interface (Modbus RTU) or via the infrared interface for connecting a KNX module. The energy meter has one output. This can be used either as a pulse output to output the active or reactive energy or as an alarm output. Up to 25 alarm values (threshold values with time delay) can be set here. The meter is calibrated according to MID and approved according to IEC. The installation width is 4 DIN modules.
€320,00
ABB ABB B21 312-100 Single phase energy meter
AC meter for measuring single-phase networks via a direct connection for currents up to a maximum of 65 A. The following values are output via a seven-segment display with up to 7 digits: active energy (class 1) and reactive energy (class 2) for import and export, power, current, voltage (LN), frequency, cos phi, power factor and apparent power. Communication can take place via the integrated RS485 interface (Modbus RTU) or via the infrared interface for connecting a KNX module. The energy meter has 2 permanently configured inputs and outputs. The output can be used either as a pulse output to output active or reactive energy or as an alarm output. Up to 25 alarm values (threshold values with a time delay) can be set here. The inputs are used to control the tariffs or to count external pulses. The resettable intermediate counter enables individual intervals to be measured. The meter also records up to 4 tariffs. The integrated clock can be used to carry out time-controlled functions. The meter is calibrated according to MID and approved according to IEC. The installation width is 2 DIN modules.
€260,00
You have seen 44 out of 44 products