ABB ABB DS203NC C20 A30 residual current circuit breaker with overcurrent protection
Residual current circuit breakers (RCBOs) offer personal and material protection as well as protection against electrically ignited fires in accordance with DIN VDE 0100-410 and DIN VDE 0100-530. They guarantee protection of three single-phase or three-phase circuits against overload and short-circuit currents, protection against sinusoidal alternating currents and pulsating currents with a smooth DC residual current component of up to 6 mA against earth. As well as fault protection (protection against indirect contact), additional protection (with IΔn ≤ 30 mA) and fire protection (with I∆n ≤ 300 mA). They meet the product standard IEC/EN 61009-1 (VDE 0664-20). Areas of application are household, commercial and industrial applications. The extensive range of accessories offers you everything you need for your installation tasks. Numerous approvals make the DS203NC fit for worldwide use. Rated switching capacity Icn = 6,000 A according to IEC/EN 61009-1 (VDE 0664-20) for RCDs (residual current devices) in residential buildings and similar applications, Icu = 10 kA according to IEC/EN 60947-2 (VDE 0660-101) for MCBs (LS) in industrial applications. RCBO DS203NC A Type A is 3-pole protected (LS), 4-pole switching and can be used in three-phase networks with or without N-conductor.
€172,99
ABB ABB S804N-C80 High Power MCB
The high-performance circuit breakers in the S800N series protect cables and lines against overload and short circuits. They have a rated short-circuit breaking capacity of 36kA at 240/415V AC. They can also be used for voltages up to 400/690V AC and for direct voltages. With its thermal tripping mechanism, it offers equally effective protection against overloads, as does its electromechanical tripping mechanism against short circuits. The S800N complies with the IEC/EN 60947-2 standard and can be used for industrial purposes. Numerous approvals make it suitable for use worldwide and the extensive range of accessories makes it even more convenient to use. Thanks to the very fast arc extinguishing, your installation is optimally protected with the S800N.
€467,67
ABB ABB FH204 A-40/0.03 residual current circuit breaker 4P type A 30 mA
The FH200 series RCCBs ensure protection for persons and installations against fault currents to earth. A comprehensive range of standard instantaneous tripping devices (AC) and Type A products are particularly suitable for installation in residential applications.
€69,02
ABB ABB DS203NC C32 A30 residual current circuit breaker with overcurrent protection
Residual current circuit breakers (RCBOs) offer personal and material protection as well as protection against electrically ignited fires in accordance with DIN VDE 0100-410 and DIN VDE 0100-530. They guarantee protection of three single-phase or three-phase circuits against overload and short-circuit currents, protection against sinusoidal alternating currents and pulsating currents with a smooth DC residual current component of up to 6 mA against earth. As well as fault protection (protection against indirect contact), additional protection (with IΔn ≤ 30 mA) and fire protection (with I∆n ≤ 300 mA). They meet the product standard IEC/EN 61009-1 (VDE 0664-20). Areas of application are household, commercial and industrial applications. The extensive range of accessories offers you everything you need for your installation tasks. Numerous approvals make the DS203NC fit for worldwide use. Rated switching capacity Icn = 6,000 A according to IEC/EN 61009-1 (VDE 0664-20) for RCDs (residual current devices) in residential buildings and similar applications, Icu = 10 kA according to IEC/EN 60947-2 (VDE 0660-101) for MCBs (LS) in industrial applications. RCBO DS203NC A Type A is 3-pole protected (LS), 4-pole switching and can be used in three-phase networks with or without N-conductor.
€211,82
ABB ABB SC201-B16NA Miniature Circuit Breaker - 1+NP - B - 16 A
SC201-B16NA Circuit breaker B-Char.,6kA,16A,1P,+NA
€23,80
ABB ABB DS203NC C25 A30 residual current circuit breaker with overcurrent protection
Residual current circuit breakers (RCBOs) offer personal and material protection as well as protection against electrically ignited fires in accordance with DIN VDE 0100-410 and DIN VDE 0100-530. They guarantee protection of three single-phase or three-phase circuits against overload and short-circuit currents, protection against sinusoidal alternating currents and pulsating currents with a smooth DC residual current component of up to 6 mA against earth. As well as fault protection (protection against indirect contact), additional protection (with IΔn ≤ 30 mA) and fire protection (with I∆n ≤ 300 mA). They meet the product standard IEC/EN 61009-1 (VDE 0664-20). Areas of application are household, commercial and industrial applications. The extensive range of accessories offers you everything you need for your installation tasks. Numerous approvals make the DS203NC fit for worldwide use. Rated switching capacity Icn = 6,000 A according to IEC/EN 61009-1 (VDE 0664-20) for RCDs (residual current devices) in residential buildings and similar applications, Icu = 10 kA according to IEC/EN 60947-2 (VDE 0660-101) for MCBs (LS) in industrial applications. RCBO DS203NC A Type A is 3-pole protected (LS), 4-pole switching and can be used in three-phase networks with or without N-conductor.
€161,84
ABB ABB S203-B40NA Miniature Circuit Breaker - 3+NP - B - 40 A
The circuit breakers of the S 200 series protect cables and lines against overload and short circuits in accordance with DIN VDE 0100-430 and DIN VDE 0100-530. They comply with the construction regulations DIN VDE 0641-11 or IEC/EN 60898-1, DIN VDE 0660-101 or IEC/EN60947-2 and UL1077. Their patented connection terminal ensures simple and safe contact and handling using a pressure plate. For better visibility when wiring, the connection opening for cables is located above the connection opening for the phase busbar. Conductor cross-sections of up to 35 mm² can be connected directly to the device via the connection terminal with insulation in protection class IP20. The extensive range of accessories offers you everything you need for your installation tasks. Numerous approvals make the S 200 fit for worldwide use. Each device is subjected to three intensive tests for quality and performance before delivery.
€111,86
ABB ABB DS201 B25 A30 residual current circuit breaker with overcurrent protection
Residual current circuit breakers (RCBOs) offer personal and material protection as well as protection against electrically ignited fires in accordance with DIN VDE 0100-410 and DIN VDE 0100-530. They ensure protection of single-phase circuits against overload and short-circuit currents, protection against sinusoidal alternating currents and pulsating currents with a smooth DC residual current component of up to 6 mA to earth. As well as fault protection (protection against indirect contact), additional protection (with IΔn ≤ 30 mA) and fire protection (with IΔn ≤ 300 mA). They meet the product standards IEC/EN 61009-1 (VDE 0664-20), IEC/EN 61009-2-1 (VDE 0664-21). Areas of application include household, commercial and industrial applications. The extensive range of accessories offers you everything you need for your installation tasks. Numerous approvals make the DS201 suitable for worldwide use. Rated switching capacity according to IEC/EN 61009 Icn = 6 kA. RCBO DS201 A Type A is 1-pole protected (LS), 2-pole switching.
€140,42
ABB ABB S203-C40NA Miniature Circuit Breaker - 3+NP - C - 40 A
The circuit breakers of the S 200 series protect cables and lines against overload and short circuits in accordance with DIN VDE 0100-430 and DIN VDE 0100-530. They comply with the construction regulations DIN VDE 0641-11 or IEC/EN 60898-1, DIN VDE 0660-101 or IEC/EN60947-2 and UL1077. Their patented connection terminal ensures simple and safe contact and handling using a pressure plate. For better visibility when wiring, the connection opening for cables is located above the connection opening for the phase busbar. Conductor cross-sections of up to 35 mm² can be connected directly to the device via the connection terminal with insulation in protection class IP20. The extensive range of accessories offers you everything you need for your installation tasks. Numerous approvals make the S 200 fit for worldwide use. Each device is subjected to three intensive tests for quality and performance before delivery.
€111,86
ABB ABB S203-B50NA Miniature Circuit Breaker - 3+NP - B - 50 A
The circuit breakers of the S 200 series protect cables and lines against overload and short circuits in accordance with DIN VDE 0100-430 and DIN VDE 0100-530. They comply with the construction regulations DIN VDE 0641-11 or IEC/EN 60898-1, DIN VDE 0660-101 or IEC/EN60947-2 and UL1077. Their patented connection terminal ensures simple and safe contact and handling using a pressure plate. For better visibility when wiring, the connection opening for cables is located above the connection opening for the phase busbar. Conductor cross-sections of up to 35 mm² can be connected directly to the device via the connection terminal with insulation in protection class IP20. The extensive range of accessories offers you everything you need for your installation tasks. Numerous approvals make the S 200 fit for worldwide use. Each device is subjected to three intensive tests for quality and performance before delivery.
€146,37
ABB ABB S201-B32NA Miniature Circuit Breaker - 1+NP - B - 32 A
The circuit breakers of the S 200 series protect cables and lines against overload and short circuits in accordance with DIN VDE 0100-430 and DIN VDE 0100-530. They comply with the construction regulations DIN VDE 0641-11 or IEC/EN 60898-1, DIN VDE 0660-101 or IEC/EN60947-2 and UL1077. Their patented connection terminal ensures simple and safe contact and handling using a pressure plate. For better visibility when wiring, the connection opening for cables is located above the connection opening for the phase busbar. Conductor cross-sections of up to 35 mm² can be connected directly to the device via the connection terminal with insulation in protection class IP20. The extensive range of accessories offers you everything you need for your installation tasks. Numerous approvals make the S 200 fit for worldwide use. Each device is subjected to three intensive tests for quality and performance before delivery.
€46,41
ABB ABB DS203NC C16 A300 residual current circuit breaker with overcurrent protection
Residual current circuit breakers (RCBOs) offer personal and material protection as well as protection against electrically ignited fires in accordance with DIN VDE 0100-410 and DIN VDE 0100-530. They guarantee protection of three single-phase or three-phase circuits against overload and short-circuit currents, protection against sinusoidal alternating currents and pulsating currents with a smooth DC residual current component of up to 6 mA against earth. As well as fault protection (protection against indirect contact), additional protection (with IΔn ≤ 30 mA) and fire protection (with I∆n ≤ 300 mA). They meet the product standard IEC/EN 61009-1 (VDE 0664-20). Areas of application are household, commercial and industrial applications. The extensive range of accessories offers you everything you need for your installation tasks. Numerous approvals make the DS203NC fit for worldwide use. Rated switching capacity Icn = 6,000 A according to IEC/EN 61009-1 (VDE 0664-20) for RCDs (residual current devices) in residential buildings and similar applications, Icu = 10 kA according to IEC/EN 60947-2 (VDE 0660-101) for MCBs (LS) in industrial applications. RCBO DS203NC A Type A is 3-pole protected (LS), 4-pole switching and can be used in three-phase networks with or without N-conductor.
€234,43
ABB ABB S201-B40NA Miniature Circuit Breaker - 1+NP - B - 40 A
The circuit breakers of the S 200 series protect cables and lines against overload and short circuits in accordance with DIN VDE 0100-430 and DIN VDE 0100-530. They comply with the construction regulations DIN VDE 0641-11 or IEC/EN 60898-1, DIN VDE 0660-101 or IEC/EN60947-2 and UL1077. Their patented connection terminal ensures simple and safe contact and handling using a pressure plate. For better visibility when wiring, the connection opening for cables is located above the connection opening for the phase busbar. Conductor cross-sections of up to 35 mm² can be connected directly to the device via the connection terminal with insulation in protection class IP20. The extensive range of accessories offers you everything you need for your installation tasks. Numerous approvals make the S 200 fit for worldwide use. Each device is subjected to three intensive tests for quality and performance before delivery.
€47,60
ABB ABB DS203NC C25 A300 residual current circuit breaker with overcurrent protection
Residual current circuit breakers (RCBOs) offer personal and material protection as well as protection against electrically ignited fires in accordance with DIN VDE 0100-410 and DIN VDE 0100-530. They guarantee protection of three single-phase or three-phase circuits against overload and short-circuit currents, protection against sinusoidal alternating currents and pulsating currents with a smooth DC residual current component of up to 6 mA against earth. As well as fault protection (protection against indirect contact), additional protection (with IΔn ≤ 30 mA) and fire protection (with I∆n ≤ 300 mA). They meet the product standard IEC/EN 61009-1 (VDE 0664-20). Areas of application are household, commercial and industrial applications. The extensive range of accessories offers you everything you need for your installation tasks. Numerous approvals make the DS203NC fit for worldwide use. Rated switching capacity Icn = 6,000 A according to IEC/EN 61009-1 (VDE 0664-20) for RCDs (residual current devices) in residential buildings and similar applications, Icu = 10 kA according to IEC/EN 60947-2 (VDE 0660-101) for MCBs (LS) in industrial applications. RCBO DS203NC A Type A is 3-pole protected (LS), 4-pole switching and can be used in three-phase networks with or without N-conductor.
€221,34
ABB ABB S201-B25NA Miniature Circuit Breaker - 1+NP - B - 25 A
The circuit breakers of the S 200 series protect cables and lines against overload and short circuits in accordance with DIN VDE 0100-430 and DIN VDE 0100-530. They comply with the construction regulations DIN VDE 0641-11 or IEC/EN 60898-1, DIN VDE 0660-101 or IEC/EN60947-2 and UL1077. Their patented connection terminal ensures simple and safe contact and handling using a pressure plate. For better visibility when wiring, the connection opening for cables is located above the connection opening for the phase busbar. Conductor cross-sections of up to 35 mm² can be connected directly to the device via the connection terminal with insulation in protection class IP20. The extensive range of accessories offers you everything you need for your installation tasks. Numerous approvals make the S 200 fit for worldwide use. Each device is subjected to three intensive tests for quality and performance before delivery.
€45,22
ABB ABB DS203NC C32 A300 residual current circuit breaker with overcurrent protection
Residual current circuit breakers (RCBOs) offer personal and material protection as well as protection against electrically ignited fires in accordance with DIN VDE 0100-410 and DIN VDE 0100-530. They guarantee protection of three single-phase or three-phase circuits against overload and short-circuit currents, protection against sinusoidal alternating currents and pulsating currents with a smooth DC residual current component of up to 6 mA against earth. As well as fault protection (protection against indirect contact), additional protection (with IΔn ≤ 30 mA) and fire protection (with I∆n ≤ 300 mA). They meet the product standard IEC/EN 61009-1 (VDE 0664-20). Areas of application are household, commercial and industrial applications. The extensive range of accessories offers you everything you need for your installation tasks. Numerous approvals make the DS203NC fit for worldwide use. Rated switching capacity Icn = 6,000 A according to IEC/EN 61009-1 (VDE 0664-20) for RCDs (residual current devices) in residential buildings and similar applications, Icu = 10 kA according to IEC/EN 60947-2 (VDE 0660-101) for MCBs (LS) in industrial applications. RCBO DS203NC A Type A is 3-pole protected (LS), 4-pole switching and can be used in three-phase networks with or without N-conductor.
€224,91
ABB ABB DS201 C20 A30 residual current circuit breaker with overcurrent protection
Residual current circuit breakers (RCBOs) offer personal and material protection as well as protection against electrically ignited fires in accordance with DIN VDE 0100-410 and DIN VDE 0100-530. They ensure protection of single-phase circuits against overload and short-circuit currents, protection against sinusoidal alternating currents and pulsating currents with a smooth DC residual current component of up to 6 mA to earth. As well as fault protection (protection against indirect contact), additional protection (with IΔn ≤ 30 mA) and fire protection (with IΔn ≤ 300 mA). They meet the product standards IEC/EN 61009-1 (VDE 0664-20), IEC/EN 61009-2-1 (VDE 0664-21). Areas of application include household, commercial and industrial applications. The extensive range of accessories offers you everything you need for your installation tasks. Numerous approvals make the DS201 suitable for worldwide use. Rated switching capacity according to IEC/EN 61009 Icn = 6 kA. RCBO DS201 A Type A is 1-pole protected (LS), 2-pole switching.
€155,89
ABB ABB S203-C63NA Miniature Circuit Breaker - 3+NP - C - 63 A
The circuit breakers of the S 200 series protect cables and lines against overload and short circuits in accordance with DIN VDE 0100-430 and DIN VDE 0100-530. They comply with the construction regulations DIN VDE 0641-11 or IEC/EN 60898-1, DIN VDE 0660-101 or IEC/EN60947-2 and UL1077. Their patented connection terminal ensures simple and safe contact and handling using a pressure plate. For better visibility when wiring, the connection opening for cables is located above the connection opening for the phase busbar. Conductor cross-sections of up to 35 mm² can be connected directly to the device via the connection terminal with insulation in protection class IP20. The extensive range of accessories offers you everything you need for your installation tasks. Numerous approvals make the S 200 fit for worldwide use. Each device is subjected to three intensive tests for quality and performance before delivery.
€183,26
ABB ABB S203-C50NA - 3+NP - C - 50 A
The circuit breakers of the S 200 series protect cables and lines against overload and short circuits in accordance with DIN VDE 0100-430 and DIN VDE 0100-530. They comply with the construction regulations DIN VDE 0641-11 or IEC/EN 60898-1, DIN VDE 0660-101 or IEC/EN60947-2 and UL1077. Their patented connection terminal ensures simple and safe contact and handling using a pressure plate. For better visibility when wiring, the connection opening for cables is located above the connection opening for the phase busbar. Conductor cross-sections of up to 35 mm² can be connected directly to the device via the connection terminal with insulation in protection class IP20. The extensive range of accessories offers you everything you need for your installation tasks. Numerous approvals make the S 200 fit for worldwide use. Each device is subjected to three intensive tests for quality and performance before delivery.
€138,04
ABB ABB DS203NC C16 A30 residual current circuit breaker with overcurrent protection
Residual current circuit breakers (RCBOs) offer personal and material protection as well as protection against electrically ignited fires in accordance with DIN VDE 0100-410 and DIN VDE 0100-530. They guarantee protection of three single-phase or three-phase circuits against overload and short-circuit currents, protection against sinusoidal alternating currents and pulsating currents with a smooth DC residual current component of up to 6 mA against earth. As well as fault protection (protection against indirect contact), additional protection (with IΔn ≤ 30 mA) and fire protection (with I∆n ≤ 300 mA). They meet the product standard IEC/EN 61009-1 (VDE 0664-20). Areas of application are household, commercial and industrial applications. The extensive range of accessories offers you everything you need for your installation tasks. Numerous approvals make the DS203NC fit for worldwide use. Rated switching capacity Icn = 6,000 A according to IEC/EN 61009-1 (VDE 0664-20) for RCDs (residual current devices) in residential buildings and similar applications, Icu = 10 kA according to IEC/EN 60947-2 (VDE 0660-101) for MCBs (LS) in industrial applications. RCBO DS203NC A Type A is 3-pole protected (LS), 4-pole switching and can be used in three-phase networks with or without N-conductor.
€183,26
ABB ABB DS201 C25 A30 residual current circuit breaker with overcurrent protection
The DS201 series is a 1P+N RCBO in two-module width for the protection of single-phase consumer circuits against overload and short-circuit currents; protection against the effects of sinusoidal alternating and direct pulsating earth fault currents; protection against indirect contacts and additional protection against direct contacts (with sensitivity = 30 mA).
€166,60
ABB ABB S203-B63NA Miniature Circuit Breaker - 3+NP - B - 63 A
The circuit breakers of the S 200 series protect cables and lines against overload and short circuits in accordance with DIN VDE 0100-430 and DIN VDE 0100-530. They comply with the construction regulations DIN VDE 0641-11 or IEC/EN 60898-1, DIN VDE 0660-101 or IEC/EN60947-2 and UL1077. Their patented connection terminal ensures simple and safe contact and handling using a pressure plate. For better visibility when wiring, the connection opening for cables is located above the connection opening for the phase busbar. Conductor cross-sections of up to 35 mm² can be connected directly to the device via the connection terminal with insulation in protection class IP20. The extensive range of accessories offers you everything you need for your installation tasks. Numerous approvals make the S 200 fit for worldwide use. Each device is subjected to three intensive tests for quality and performance before delivery.
€170,17
ABB ABB S201-B20NA Miniature Circuit Breaker - 1+NP - B - 20 A
The circuit breakers of the S 200 series protect cables and lines against overload and short circuits in accordance with DIN VDE 0100-430 and DIN VDE 0100-530. They comply with the construction regulations DIN VDE 0641-11 or IEC/EN 60898-1, DIN VDE 0660-101 or IEC/EN60947-2 and UL1077. Their patented connection terminal ensures simple and safe contact and handling using a pressure plate. For better visibility when wiring, the connection opening for cables is located above the connection opening for the phase busbar. Conductor cross-sections of up to 35 mm² can be connected directly to the device via the connection terminal with insulation in protection class IP20. The extensive range of accessories offers you everything you need for your installation tasks. Numerous approvals make the S 200 fit for worldwide use. Each device is subjected to three intensive tests for quality and performance before delivery.
€45,22
ABB ABB DS203NC C20 A300 residual current circuit breaker with overcurrent protection
Residual current circuit breakers (RCBOs) offer personal and material protection as well as protection against electrically ignited fires in accordance with DIN VDE 0100-410 and DIN VDE 0100-530. They guarantee protection of three single-phase or three-phase circuits against overload and short-circuit currents, protection against sinusoidal alternating currents and pulsating currents with a smooth DC residual current component of up to 6 mA against earth. As well as fault protection (protection against indirect contact), additional protection (with IΔn ≤ 30 mA) and fire protection (with I∆n ≤ 300 mA). They meet the product standard IEC/EN 61009-1 (VDE 0664-20). Areas of application are household, commercial and industrial applications. The extensive range of accessories offers you everything you need for your installation tasks. Numerous approvals make the DS203NC fit for worldwide use. Rated switching capacity Icn = 6,000 A according to IEC/EN 61009-1 (VDE 0664-20) for RCDs (residual current devices) in residential buildings and similar applications, Icu = 10 kA according to IEC/EN 60947-2 (VDE 0660-101) for MCBs (LS) in industrial applications. RCBO DS203NC A Type A is 3-pole protected (LS), 4-pole switching and can be used in three-phase networks with or without N-conductor.
€224,91