Description The Multiplus 24/3000/70-50 from Victron (MPN PMP242301011) is a combination unit consisting of a 24V 2400W sine-wave inverter and a battery charger. The permanently integrated battery charger delivers an impressive 70A, so even large batteries can be fully charged quickly when shore or grid power is available. The 24V sine-wave inverter built into the Multiplus converts the power from your battery into 230V alternating current. Thanks to the true sine wave, the power quality is perfectly suited even for sensitive electronic devices. In addition to the two integrated device types, a lightning-fast 50A transfer switch is also built in, which allows numerous grid-connected solutions to be implemented. For system integration, a COM port is available in addition to the VE.Bus port, which makes virtually limitless networking of the Multiplus possible.Comprehensive and flexible in use Because it has a lightning-fast 50A transfer switch in addition to the inverter and charger, it is an ideal inverter for motorhomes, boats and yachts, and for the grid-connected field of uninterruptible power supply in the event of grid fluctuations or power outages. It is also suitable for grid-connected self-consumption systems that only draw power from the utility when battery power is no longer sufficient, or as a UPS solution in which the Multiplus steps in when power from the grid operator suddenly fails and thus ensures an uninterrupted power supply.Key features of the Multiplus C 24/3000/70-50
2400W continuous power and 6000W peak power, for 24V battery voltage
Combination unit consisting of an inverter with transfer switch and a 70A battery charger
delivers pure 230V sine-wave voltage and a clean 50Hz frequency
VE.Bus communication port provides extensive options for networking, system integration, configuration and control of Victron Multiplus units.
supports three-phase operation (3 identical units of the same model required)
Multiplus units can be connected in parallel; up to 6 units can be linked in parallel, significantly increasing system power when required
2 AC outputs from Multiplus 3000 and larger. Devices that should only run when grid power is available can then be connected to the second output, for example
from the Multiplus 3000, a COM port is available in addition to the VE.Bus port, so there are effectively no more limits to system integration
PowerControl function enables working with limited generator power as well as restricted shore or grid power
PowerAssist function enables a “power boost” for generators and shore power support when required
can be used as a UPS solution for uninterruptible power supply, thanks to the integrated transfer switch with 16A or 50A
can be used for grid-connected self-consumption systems that only draw power from the grid operator when battery capacity is no longer sufficient or other programmable events have occurred
compatible with numerous Victron control and display panels
Three-phase operation possible with identical MultiPlus inverters
Massive power expansion possible Besides parallel connection, three units of the same model can also be configured for a three-phase output. But that is not all: up to six sets of three units can be connected in parallel to achieve a huge 75 kW / 90 kVA inverter and over 2,000 A of charging capacity (calculated with the 5000 version)PowerControl – Working with limited generator power, restricted shore or grid power The MultiPlus is a very powerful battery charger. It therefore draws a lot of current from the generator or the shore power supply (almost 10A per 5kVA Multi at 230 VAC). With the Multi Control remote panel, the maximum grid or generator current to be drawn can be set. The MultiPlus then takes other connected AC loads into account and uses only the power that is still “left over” for charging. This prevents the generator or the shore power connection from being overloaded. PowerAssist – “Power boost” for generators and shore power support This function gives the PowerControl principle a new dimension. It allows the MultiPlus to support alternative sources that are undersized. Load peaks often only occur for a limited period of time. In such a case, the MultiPlus ensures that weak shore power or generator output is immediately compensated by energy from the battery. Backup system: AC power even during a grid outage The Multiplus can be used in both off-grid and grid-connected PV systems as well as in other alternative energy systems. Software for detecting a grid outage is available.Simple system configuration If settings on a single unit need to be changed, this can be done within a few minutes using a DIP-switch setting procedure. Parallel and three-phase systems can be configured with the VE.Bus Quick Configure and VE.Bus System Configurator software. Monitoring options and local control Several options are available: battery monitor, Multi Control panel, VE.Net Blue Power panel, Color Control panel, smartphone or tablet (Bluetooth Smart), laptop or computer (USB or RS232). Remote monitoring and control Victron Ethernet Remote, Victron Global Remote and the Color Control Panel allow remote maintenance and remote monitoring of the MultiPlus. In addition, system data can be stored and viewed free of charge on the VRM (Victron Remote Management) website.Remote configuration If systems with a Color Control panel are connected to Ethernet, they can be accessed and settings can be changed remotely. Scope of delivery: 1x Victron PMP242301011 Multiplus 24/3000/70-50 combination unit consisting of a 24V 2400W sine-wave inverter + 24V 70A battery charger + 50A transfer switch 1x User manual
Victron MultiPlus 24/3000/70-50 24V 230V 2400W 6000W inverter 70A charger
Product form
949,00 €
Incl. VAT
plus shipping costs
Guaranteed safe & secure checkout.
Free Shipping for all orders over € 39 (except freight goods).30 days Money-back guaranteeOwn warehouse at our company headquarters
Shipping from Veitshöchheim
We ship your order from our own warehouse in Veitshöchheim. Pickup on site is possible by arrangement.
Our shipping promise
Orders can be returned or exchanged within 30 days of receipt of delivery, provided they are in their original condition. We deliver throughout Europe. Your order is carefully packed and delivered to the desired location. You can find the expected delivery time directly next to the price of the respective product.
Kerndaten auf einen Blick
Wechselrichterleistung 2.400 W Garantie 5 Jahre Hersteller-Artikelnummer PMP242301011
Herstellerangaben und Produktsicherheit
Hersteller
Victron Energy B.V., de Paal 35, 1351JG, Almere, Netherlands, www.victronergy.de, Sales@victronenergy.com, 00000000 ,
Sicherheitshinweise
Bitte beachten Sie die Sicherheits- und Montagehinweise in der Bedienungsanleitung des Herstellers.
Persönliche Beratung
Sie sind unsicher, ob dieses Produkt zu Ihrer Anlage passt? Wir beraten Sie gern persönlich.
Abholung in Veitshöchheim nach Absprache.
Technische Daten Battery outputs: female
Battery voltage: 24V
Continuous power: 2400W
Self-consumption at no load: 20W
Self-consumption in standby: 10W
Frequency range: 50Hz / +-0.1Hz
Warranty: 5 years manufacturer's guarantee 2
Weight: 18 kg
Manufacturer: Victron Energy
Nominal output voltage: 230V AC / alternating current
Protection rating (IP): IP21
Sine wave: true sine wave
Voltage regulation: 24V DC / 230V AC
Temperature range: VE.Bus
Transfer switch integrated: Yes - 1 piece
Transfer switch rating: 50A
SKU: SL-VIC-MULTIPLUS243000-0
Barcode: 8719076045175
Description The Multiplus 24/3000/70-50 from Victron (MPN PMP242301011) is a combination unit consisting of a 24V 2400W sine-wave inverter and a battery charger. The permanently integrated battery charger delivers an impressive 70A, so even large batteries can be fully charged quickly when shore or grid power is available. The 24V sine-wave inverter built into the Multiplus converts the power from your battery into 230V alternating current. Thanks to the true sine wave, the power quality is perfectly suited even for sensitive electronic devices. In addition to the two integrated device types, a lightning-fast 50A transfer switch is also built in, which allows numerous grid-connected solutions to be implemented. For system integration, a COM port is available in addition to the VE.Bus port, which makes virtually limitless networking of the Multiplus possible.Comprehensive and flexible in use Because it has a lightning-fast 50A transfer switch in addition to the inverter and charger, it is an ideal inverter for motorhomes, boats and yachts, and for the grid-connected field of uninterruptible power supply in the event of grid fluctuations or power outages. It is also suitable for grid-connected self-consumption systems that only draw power from the utility when battery power is no longer sufficient, or as a UPS solution in which the Multiplus steps in when power from the grid operator suddenly fails and thus ensures an uninterrupted power supply.Key features of the Multiplus C 24/3000/70-50
2400W continuous power and 6000W peak power, for 24V battery voltage
Combination unit consisting of an inverter with transfer switch and a 70A battery charger
delivers pure 230V sine-wave voltage and a clean 50Hz frequency
VE.Bus communication port provides extensive options for networking, system integration, configuration and control of Victron Multiplus units.
supports three-phase operation (3 identical units of the same model required)
Multiplus units can be connected in parallel; up to 6 units can be linked in parallel, significantly increasing system power when required
2 AC outputs from Multiplus 3000 and larger. Devices that should only run when grid power is available can then be connected to the second output, for example
from the Multiplus 3000, a COM port is available in addition to the VE.Bus port, so there are effectively no more limits to system integration
PowerControl function enables working with limited generator power as well as restricted shore or grid power
PowerAssist function enables a “power boost” for generators and shore power support when required
can be used as a UPS solution for uninterruptible power supply, thanks to the integrated transfer switch with 16A or 50A
can be used for grid-connected self-consumption systems that only draw power from the grid operator when battery capacity is no longer sufficient or other programmable events have occurred
compatible with numerous Victron control and display panels
Three-phase operation possible with identical MultiPlus inverters
Massive power expansion possible Besides parallel connection, three units of the same model can also be configured for a three-phase output. But that is not all: up to six sets of three units can be connected in parallel to achieve a huge 75 kW / 90 kVA inverter and over 2,000 A of charging capacity (calculated with the 5000 version)PowerControl – Working with limited generator power, restricted shore or grid power The MultiPlus is a very powerful battery charger. It therefore draws a lot of current from the generator or the shore power supply (almost 10A per 5kVA Multi at 230 VAC). With the Multi Control remote panel, the maximum grid or generator current to be drawn can be set. The MultiPlus then takes other connected AC loads into account and uses only the power that is still “left over” for charging. This prevents the generator or the shore power connection from being overloaded. PowerAssist – “Power boost” for generators and shore power support This function gives the PowerControl principle a new dimension. It allows the MultiPlus to support alternative sources that are undersized. Load peaks often only occur for a limited period of time. In such a case, the MultiPlus ensures that weak shore power or generator output is immediately compensated by energy from the battery. Backup system: AC power even during a grid outage The Multiplus can be used in both off-grid and grid-connected PV systems as well as in other alternative energy systems. Software for detecting a grid outage is available.Simple system configuration If settings on a single unit need to be changed, this can be done within a few minutes using a DIP-switch setting procedure. Parallel and three-phase systems can be configured with the VE.Bus Quick Configure and VE.Bus System Configurator software. Monitoring options and local control Several options are available: battery monitor, Multi Control panel, VE.Net Blue Power panel, Color Control panel, smartphone or tablet (Bluetooth Smart), laptop or computer (USB or RS232). Remote monitoring and control Victron Ethernet Remote, Victron Global Remote and the Color Control Panel allow remote maintenance and remote monitoring of the MultiPlus. In addition, system data can be stored and viewed free of charge on the VRM (Victron Remote Management) website.Remote configuration If systems with a Color Control panel are connected to Ethernet, they can be accessed and settings can be changed remotely. Scope of delivery: 1x Victron PMP242301011 Multiplus 24/3000/70-50 combination unit consisting of a 24V 2400W sine-wave inverter + 24V 70A battery charger + 50A transfer switch 1x User manual