Energy meter

29 Products

  • ABB DS203NC C32 A300 Fehlerstrom Schutzschalter mit Überstromschutz - NeueEnergie24

    ABB ABB DS203NC C32 A300 fault current circuit breaker with overcurrent protection

    7-14 Werktage  Lieferzeit je nach Produkt. Speditionsware nach Terminabsprache länger. Bestellware wird erst beim Hersteller geordert und kann daher verzögert sein.

    FI/LS switches (RCBOS) offer personal and material protection as well as protection against electrically ignited fires in accordance with DIN VDE 0100-410 and DIN VDE 0100-530. They ensure protection of three single-phase or three-phase current circles against overload and short-circuit currents, protection for sinus-shaped alternating currents and pulsating streams with a smooth proportion of the same error of up to 6 mA to earth. As well as error protection (protection for indirect touch), additional protection (with iδn ≤ 30 mA) and fire protection (with i∆n ≤ 300 mA). They meet the IEC/EN 61009-1 product standard (VDE 0664-20). Areas of application are household, commercial and industrial applications. The extensive range of accessories offers you everything you need for your installation tasks. Numerous approvals make the DS203NC fit for worldwide use. Dimensioning capacity ICN = 6,000 A according to IEC/EN 61009-1 (VDE 0664-20) for RCDs (residual current protection devices) in residential construction and similar applications, ICU = 10 KA according to IEC/EN 60947-2 (VDE 0660-101) for MCBS (LS) in industrial applications. RCBO DS203NC A Type A is 3-pole (LS), 4-pole switching and can be used in three-phase networks with or without N conductor.

    7-14 Werktage  Lieferzeit je nach Produkt. Speditionsware nach Terminabsprache länger. Bestellware wird erst beim Hersteller geordert und kann daher verzögert sein.

    €135,95

  • ABB DS203NC C20 A300 Fehlerstrom Schutzschalter mit Überstromschutz - NeueEnergie24

    ABB Fig. DS203NC C20 A300 fault current circuit breaker with overcurrent protection

    7-14 Werktage  Lieferzeit je nach Produkt. Speditionsware nach Terminabsprache länger. Bestellware wird erst beim Hersteller geordert und kann daher verzögert sein.

    FI/LS switches (RCBOS) offer personal and material protection as well as protection against electrically ignited fires in accordance with DIN VDE 0100-410 and DIN VDE 0100-530. They ensure protection of three single-phase or three-phase current circles against overload and short-circuit currents, protection for sinus-shaped alternating currents and pulsating streams with a smooth proportion of the same error of up to 6 mA to earth. As well as error protection (protection for indirect touch), additional protection (with iδn ≤ 30 mA) and fire protection (with i∆n ≤ 300 mA). They meet the IEC/EN 61009-1 product standard (VDE 0664-20). Areas of application are household, commercial and industrial applications. The extensive range of accessories offers you everything you need for your installation tasks. Numerous approvals make the DS203NC fit for worldwide use. Dimensioning capacity ICN = 6,000 A according to IEC/EN 61009-1 (VDE 0664-20) for RCDs (residual current protection devices) in residential construction and similar applications, ICU = 10 KA according to IEC/EN 60947-2 (VDE 0660-101) for MCBS (LS) in industrial applications. RCBO DS203NC A Type A is 3-pole (LS), 4-pole switching and can be used in three-phase networks with or without N conductor.

    7-14 Werktage  Lieferzeit je nach Produkt. Speditionsware nach Terminabsprache länger. Bestellware wird erst beim Hersteller geordert und kann daher verzögert sein.

    €149,00

  • ABB DS203NC C16 A300 Fehlerstrom Schutzschalter mit Überstromschutz - NeueEnergie24

    ABB ABB DS203NC C16 A300 fault current circuit breaker with overcurrent protection

    7-14 Werktage  Lieferzeit je nach Produkt. Speditionsware nach Terminabsprache länger. Bestellware wird erst beim Hersteller geordert und kann daher verzögert sein.

    FI/LS switches (RCBOS) offer personal and material protection as well as protection against electrically ignited fires in accordance with DIN VDE 0100-410 and DIN VDE 0100-530. They ensure protection of three single-phase or three-phase current circles against overload and short-circuit currents, protection for sinus-shaped alternating currents and pulsating streams with a smooth proportion of the same error of up to 6 mA to earth. As well as error protection (protection for indirect touch), additional protection (with iδn ≤ 30 mA) and fire protection (with i∆n ≤ 300 mA). They meet the IEC/EN 61009-1 product standard (VDE 0664-20). Areas of application are household, commercial and industrial applications. The extensive range of accessories offers you everything you need for your installation tasks. Numerous approvals make the DS203NC fit for worldwide use. Dimensioning capacity ICN = 6,000 A according to IEC/EN 61009-1 (VDE 0664-20) for RCDs (residual current protection devices) in residential construction and similar applications, ICU = 10 KA according to IEC/EN 60947-2 (VDE 0660-101) for MCBS (LS) in industrial applications. RCBO DS203NC A Type A is 3-pole (LS), 4-pole switching and can be used in three-phase networks with or without N conductor.

    7-14 Werktage  Lieferzeit je nach Produkt. Speditionsware nach Terminabsprache länger. Bestellware wird erst beim Hersteller geordert und kann daher verzögert sein.

    €134,00

  • ABB DS201 C25 A30 Fehlerstrom Schutzschalter mit Überstromschutz - NeueEnergie24

    ABB ABB DS201 C25 A30 fault current circuit breaker with overcurrent protection

    7-14 Werktage  Lieferzeit je nach Produkt. Speditionsware nach Terminabsprache länger. Bestellware wird erst beim Hersteller geordert und kann daher verzögert sein.

    DThe DS201 series is a 1p+N RCBO in two module width for the protection of single-phase end consumer circuits against overload and short-circuit currents; Protection against the effects of sinus-shaped alternating and direct pulsating earth closing currents; Protection against indirect contacts and additional protection against direct contacts (with sensitivity = 30 mA).

    7-14 Werktage  Lieferzeit je nach Produkt. Speditionsware nach Terminabsprache länger. Bestellware wird erst beim Hersteller geordert und kann daher verzögert sein.

    €94,00

  • ABB B23 212 - 100 YCU.00152 Drehstromzähler - NeueEnergie24

    ABB Fig B23 212-100 YCU.00152 three-phase meter

    7-14 Werktage  Lieferzeit je nach Produkt. Speditionsware nach Terminabsprache länger. Bestellware wird erst beim Hersteller geordert und kann daher verzögert sein.

    The three-ladement or four-conductor rotary power meter via a direct connection up to a maximum of 65 A. The following values ​​are output via a white backlit display with up to 7 spots: activity energy (class 1) and blind energy (class 2) for import and export, services, currents, voltages (L-L, L-N), frequency, COS phi, power factor and apparent performance, both ever Phase as well as overall. Communication can be via the integrated interface RS485 (Modbus RTU) or via the infrared interface to connect a KNX module. The energy meter has an outcome. This can be used as an impulse output for output of the active or blind energy or as an alarm output. Up to 25 alarm values ​​(threshold values ​​with time delay) can be set here. The counter is calibrated according to mid and approved according to IEC. The installation width is 4 DIN modules.

    7-14 Werktage  Lieferzeit je nach Produkt. Speditionsware nach Terminabsprache länger. Bestellware wird erst beim Hersteller geordert und kann daher verzögert sein.

    €229,00

They have 29 from 29 Seen products

Registration

Did you forget your password?

You don't have any account yet?
Create an account